Type SHD-GC Special Cables EPR Insulated And CPE / TPU Jacket Heat Resistant
APPLICATION
Trailing cable on ac mining equipment where service conditions are
severe and maximum safety is mandatory; such as
power shovels and drag lines in open-pit mines, quarries, gantry
cranes and slag reclaiming.
Used for high voltage distribution in underground mines where
frequent relocation is necessary or where extra
flexibility and toughness is desired.
Meets all requirements of ICEA S-75-381.
CHARACTERISTIC
Excellent flexibility
Highly ozone, sun, weather and flame resistant
Excellent impact and abrasion resistant
Rated and flexible at -500C
Oil and heat resistant
1. Phase, Grounding Conductors, Ground check conductors: Soft or annealed tinned coated copper
conductor, rope lay flexible stranding per ASTM B172
2. Conductor Shield: A helically applied semiconducting tape.
3. Insulation: High quality, heat, moisture, ozone and thermosetting ethylene
propylene rubber (EPR)
meeting ICEA.
4. Insulation Shield: An overlapped semiconducting tape shall be applied over the
insulation.
5. Metallic Component: A composite fiber-copper braid shield, tinned coated copper wires,
Coverage
minimum 60 ,with colored fibers for phase identification (black,
white, red).
6. Assembly: Phase, ground check and grounding conductors cabled together with
hygroscopic fillers and a
binder tape.
7. Ground Check: Polypropylene insulation yellow colored for identification.
8. Jacket(CPE): Heavy duty or extra heavy duty chlorinated polyethylene (CPE)
compound, applied in one
layer over a fibrous reinforcement layer, Black or other colors can
be provided.
8. Jacket(TPU): Extra heavy duty, high torsion resistant, integral-filled,
thermoplastic Polyurethane jacket,
Black or other colors can be provided.
Technical Data
SHD-GC 2 kV | |||||||||
Selection data | |||||||||
Power conductor size | Power conductor stranding | Nominal thickness of insulation | Jacket thickness | Grounding conductor | Approximate overall diameter | Ampacity 40°Cambient temperature | |||
Size | Stranding | ||||||||
AWG or MCM | Inches | Inches | AWG | Inches | A | ||||
6 | 133 | 7x19 | 0.070 | 0.155 | 10 | 49 | 7x7 | 1.26 | 93 |
4 | 259 | 7x37 | 0.070 | 0.155 | 8 | 133 | 7x19 | 1.36 | 122 |
2 | 259 | 7x37 | 0.070 | 0.170 | 6 | 133 | 7x19 | 1.55 | 159 |
1 | 259 | 7x37 | 0.080 | 0.170 | 5 | 133 | 7x19 | 1.71 | 184 |
1/0 | 266 | 19x14 | 0.080 | 0.190 | 4 | 259 | 7x37 | 1.81 | 211 |
2/0 | 342 | 19x18 | 0.080 | 0.205 | 3 | 259 | 7x39 | 1.94 | 243 |
3/0 | 418 | 19x22 | 0.080 | 0.205 | 2 | 259 | 7x37 | 2.07 | 279 |
4/0 | 532 | 19x28 | 0.080 | 0.220 | 1 | 259 | 7x37 | 2.24 | 321 |
250 | 627 | 19x33 | 0.095 | 0.220 | 1/0 | 266 | 19x14 | 2.44 | 355 |
300 | 740 | 37x20 | 0.095 | 0.235 | 1/0 | 266 | 19x14 | 2.70 | 395 |
350 | 888 | 37x24 | 0.095 | 0.235 | 2/0 | 342 | 19x18 | 2.73 | 435 |
500 | 1221 | 37x33 | 0.095 | 0.265 | 4/0 | 532 | 19x28 | 3.10 | 536 |
SHD-GC 5 kV | |||||||||
Selection data | |||||||||
Power conductor size | Power conductor stranding | Nominal thickness of insulation | Jacket thickness | Grounding conductor | Approximate overall diameter | Ampacity 40°Cambient temperature | |||
Size | Stranding | ||||||||
AWG or MCM | Inches | Inches | AWG | Inches | A | ||||
6 | 133 | 7x19 | 0.110 | 0.185 | 10 | 49 | 7x7 | 1.51 | 93 |
4 | 259 | 7x37 | 0.110 | 0.185 | 8 | 133 | 7x19 | 1.60 | 122 |
2 | 259 | 7x37 | 0.110 | 0.205 | 6 | 133 | 7x19 | 1.79 | 159 |
1 | 259 | 7x37 | 0.110 | 0.205 | 5 | 133 | 7x19 | 1.88 | 184 |
1/0 | 266 | 19x14 | 0.110 | 0.220 | 4 | 259 | 7x37 | 1.98 | 211 |
2/0 | 342 | 19x18 | 0.110 | 0.220 | 3 | 259 | 7x37 | 2.12 | 243 |
3/0 | 418 | 19x22 | 0.110 | 0.235 | 2 | 259 | 7x37 | 2.26 | 279 |
4/0 | 532 | 19x28 | 0.110 | 0.235 | 1 | 259 | 7x37 | 2.51 | 321 |
250 | 627 | 19x33 | 0.120 | 0.250 | 1/0 | 266 | 19x14 | 2.57 | 355 |
350 | 888 | 37x24 | 0.120 | 0.265 | 2/0 | 342 | 19x18 | 2.83 | 435 |
500 | 1221 | 37x33 | 0.120 | 0.280 | 4/0 | 532 | 19x28 | 3.18 | 536 |
SHD-GC 8 kV | |||||||||
Selection data | |||||||||
Power conductor size | Power conductor stranding | Nominal thickness of insulation | Jacket thickness | Grounding conductor | Approximate overall diameter | Ampacity 40°Cambient temperature | |||
Size | Stranding | ||||||||
AWG or MCM | Inches | Inches | AWG | Inches | A | ||||
4 | 259 | 7x37 | 0.150 | 0.205 | 8 | 133 | 7x19 | 1.93 | 93 |
2 | 259 | 7x37 | 0.150 | 0.220 | 6 | 133 | 7x19 | 2.02 | 122 |
1 | 259 | 7x37 | 0.150 | 0.220 | 5 | 133 | 7x19 | 2.10 | 159 |
1/0 | 266 | 19x14 | 0.150 | 0.220 | 4 | 259 | 7x37 | 2.21 | 184 |
2/0 | 342 | 19x18 | 0.150 | 0.235 | 3 | 259 | 7x37 | 2.34 | 211 |
3/0 | 418 | 19x22 | 0.150 | 0.250 | 2 | 259 | 7x37 | 4.49 | 243 |
4/0 | 532 | 19x28 | 0.150 | 0.250 | 1 | 259 | 7x37 | 2.63 | 279 |
250 | 627 | 19x33 | 0.150 | 0.250 | 1/0 | 266 | 19x14 | 2.75 | 321 |
350 | 888 | 37x24 | 0.150 | 0.280 | 2/0 | 342 | 19x18 | 3.05 | 355 |
500 | 1221 | 37x33 | 0.150 | 0.295 | 4/0 | 532 | 19x28 | 3.39 | 435 |
SHD-GC 15 kV | |||||||||
Selection data | |||||||||
Power conductor size | Power conductor stranding | Nominal thickness of insulation | Jacket thickness | Grounding conductor | Approximate overall diameter | Ampacity 40°Cambient temperature | |||
Size | Stranding | ||||||||
AWG or MCM | Inches | Inches | AWG | Inches | A | ||||
2 | 259 | 7x37 | 0.210 | 0.235 | 6 | 133 | 7x19 | 2.31 | 164 |
1 | 259 | 7x37 | 0.210 | 0.235 | 5 | 133 | 7x19 | 2.40 | 187 |
1/0 | 266 | 19x14 | 0.210 | 0.250 | 4 | 259 | 7x37 | 2.52 | 215 |
2/0 | 342 | 19x18 | 0.210 | 0.250 | 3 | 259 | 7x37 | 2.60 | 246 |
3/0 | 418 | 19x22 | 0.210 | 0.265 | 2 | 259 | 7x37 | 2.79 | 283 |
4/0 | 532 | 19x28 | 0.210 | 0.265 | 1 | 259 | 7x37 | 2.90 | 325 |
250* | 627 | 19x33 | 0.210 | 0.265 | 1/0 | 266 | 19x14 | 3.05 | 355 |
350* | 888 | 37x24 | 0.210 | 0.280 | 2/0 | 342 | 19x18 | 3.31 | 435 |
500* | 1221 | 37x33 | 0.210 | 0.295 | 4/0 | 532 | 19x28 | 3.72 | 536 |
SHD-GC 25 kV | |||||||||
Selection data | |||||||||
Power conductor size | Power conductor stranding | Nominal thickness of insulation | Jacket thickness | Grounding conductor | Approximate overall diameter | Ampacity 40°Cambient temperature | |||
Size | Stranding | ||||||||
AWG or MCM | Inches | Inches | AWG | Inches | A | ||||
2 | 259 | 7x37 | 0.295 | 0.235 | 6 | 133 | 7x19 | 2.55 | 178 |
1 | 259 | 7x37 | 0.295 | 0.265 | 5 | 133 | 7x19 | 2.86 | 191 |
1/0 | 266 | 19x14 | 0.295 | 0.265 | 4 | 259 | 7x37 | 2.91 | 218 |
2/0 | 342 | 19x18 | 0.295 | 0.280 | 3 | 259 | 7x37 | 3.06 | 249 |
3/0 | 418 | 19X22 | 0.295 | 0.280 | 2 | 259 | 7x37 | 3.19 | 286 |
4/0 | 532 | 19x28 | 0.295 | 0.295 | 1 | 259 | 7x37 | 3.34 | 327 |
250* | 627 | 19x33 | 0.295 | 0.295 | 1/0 | 266 | 19x14 | 3.43 | 360 |
350* | 888 | 37x24 | 0.295 | 0.295 | 2/0 | 342 | 19x18 | 3.66 | 435 |
CN Cable Group Co., Ltd.
ABOUT CN CABLE GROUP
CN Cable Group specializes in the fields of development, design, production, sales, installation and technology service of wires and cables, accessories. We are one of the most experienced manufacturers and suppliers in the global markets.
Our Products mainly include: 500KV and below power cables, bare conductors (AAC, ACSR, ACAR, AAAC, galvanized steel wires, etc.), ABC cables, mining cables, rubber cables, computer cables, telephone cables, control cables, instrument cables, fiber cables, building wires, flat cables, silicon cables, environmental protection cables, cable accessories, etc. The above products had passed the management system certificate of ISO 9001:2015 and ISO 14001:2015 and ISO18001:2007, CE certificate and IEC certificate, etc.
There are large quantities of skilled workers (more than 300 persons) in the factory. Most of them have rich experiences in the field of cable manufacturing, engineering technology, and enterprise management. More than 40 persons are of senior professional and technical personnel, who are the upgraded technology experts and academic technology leaders. Design and production of all of our products are strictly according to the relative standards, GB, IEC, BS, DIN, ASTM, UL, NFC, CSA, and Australian standard, etc. Our products have been exported to more than 100 countries and regions, such as USA, Canada, Brazil, Chile, Peru, South Africa, Tanzania, Kenya, Uganda, Nigeria, Togo, Middle East and Southeast Asia and other countries and regions.
In addition, our professional service team with the fastest speed, best service attitude and best service quality will continue to technical advice, technical guidance, technical training, on-site construction, etc. We will try our best to do well in everything before sales, in sales and after sales with our enthusiasm.
Quality are always the first, must be guaranteed. You are welcome for your witness.